Kamis, 16 Juni 2011

PT. MADITECH MEDIKA FARMA




PT. MADITECH MEDIKA FARMA  is well established in   Medical,   Laboratory,   Instrument    and Hospital furniture.
Our core Bussiness included Radioterapy, Laboratory Pantology Clinic/Anatomy,   Operating  Theatre  equipment, X-Ray, Fisiotheraphy, USG, ECG, EEG, EMG,  CT-Scan,  MRI,  Treadmill,  Spirometre, Bonedencity, Dental Unit, Dental X-Ray, Intensive Care, Medical Ventilator, Medical Gas Piping, Electrical Hospital Bads, Medical Apparel & Textile, Emergency Product, Ambulance ….etc.
At present we are as Sole Agent for Radiotherapy as like as Cobalt 60 and Linex from Radon “TURKI”. We do supply the material/Equipment, but we are also involve in Design, Install, Service, Testing and commisioning all Product offered.  We are proffesional in our  field  and  offer  complete  program  for serve you with further details.
Our mission is to serve our customer by providing the reliable  and  high  quality  products  with  cost effective and after sales services to meet their requirements and expectations.


For more Indormation :
PT. MADITECH MEDIKA FARMA
Jl. Raya Lenteng Agung No. 4
JAKARTA SELATAN 12610 INDONESIA

Phone : 62-21-7873058,   7800375
Fax : 62-21-7873058

E-mail : marketing.maditech@gmail.com

Mobile : 081213786999
Mobile : 087878196999

MythoVent2 Ventilator



The MythoVent2 offers the first system worldwide that integrates a state of the art ventilator and a comprehensive vital signs monitoring.

The complete respiratory monitoring of the MythoVent, including breath frequency, capnometry and exspiratory oxymetry is enlarged at the MythoVent2 by the vital signs monitoring Das umfassende atemmechanische Monitoring des MythoVent, inklusive Atemfrequenz, Capnometrie und exspiratorischer Oxymetrie, wird im MythoVent2 um die Basisfunktionen des Vitalparameter-Monitorings erweitert:
  • 3- or 5-lead ECG
  • Arrhythmia
  • ST-Analysis
  • 2 × Invasive blood pressure
  • Non-invasive blood pressure
  • Pulsoxymetrie (SPO2)
  • 2 x Temperature

If the MythoVent2 is used as a vital signs monitor solely all vital parameters can be displayed due to the free screen configuration.
The entire alarm monitoring of all vital parameters is strictly separated from the ventilation parameters and has a separate setup menu. The alarm limits for the vital parameters may be set manually or automatically by the system.
When using the ventilator system and the vital signs monitoring of the MythoVent2 at the same time the displayed parameters can be combined in any way.

Modern ventilation modes

The system provides all modern ventilation modes and gives the doctor the highest flexibility in setting the parameters to adjust the ventilation to the exact needs of the patient.
To these settings belong the pressure support of the spontaneous breath and the fine tunable trigger for the mandatory breath with both pressure- and modern flow-triggering.
The fast and safe weaning of the patient from the mechanical ventilation is the main challenge for the intensive care medicine today. The MythoVent is designed to support and stabilize the spontaneous breath of the patient.

Optional adaptive cuff pressure control

Exceptional innovative is the intelligent cuff pressure control. The cuff pressure is adjusted automatically as an offset to the respiratory and PEEP pressure and provides a save closing pressure in the trachea. The cuff pressure curve is displayed as an overlay to the respiratory pressure curve.

Use of single- and dual-limb-system

The only part of the device that has to be cleaned, sterilized and disinfected is the aluminum-cassette. It can be removed fast and easy by a simple press of a button. Since the cassette consists of metal it is almost everlasting - even in permanent clinical use.
Through a simple change of the cassette, the MythoVent can be used with coaxial- as well as dual-limb breathing system with no problem.

Integrated intelligent drug-nebulizer

Another feature is the integrated pneumatic control unit for a drug nebulizer. The system MythoVent drives the nebulizer during the first 75 percent of the inspiratory phase. It is ensured that the drugs always reach the patient in the most effective way and the filter systems of the breathing circuit are kept free.

Integrated high resolution color display

The ventilator MythoVent offers a high resolution 6 channel 10.4“ LCD color display. It allows at the same time the display of up to 8 dynamic curves and 12 numeric fields for the display of ventilation parameters.
The display may be individually configured to the needs of the user by free arrangement and choice of color for the displayed parameters and measured curves.

Optional external display

The MythoVent and MythoVent2 have an optional port for connecting an additional monitor. The content of the internal display is mirrored on a large-sized TFT-screen, so that the curves and values can be read clearly even from greater distance.

Easy and fast alarm-limit-adaptation

Alarm limits for ventilation parameters may be set manually or automatically by the system. The trend graphic of the ventilation parameters during the last half hour helps to set the upper and lower limits easy and gradient adaptive.

Individual configurations

Individual settings — screen setup, alarm limits, ventilation- and monitoring-settings — can be stored one by one or all together as individual configurations and are then available every time.

Optional patient-side CO2- and O2-measuring

The exspiratory concentration is measured via a sample line connected to the front of the device. For that purpose a small sample volume is permanently extracted near the patient directly at the HME filter and guided to the device.

Leightweight design

Less weight and small dimensions allow highest flexibility in patient handling, mounting systems and in-house transportation.

Update/Upgrade with standart RS232 service interface

To remain up to date the MythoVent comes with a standart RS232 service interface. With this interface it is easily possible to upgrade the firmware and get new features.



Ventilation modes

  • Assisted/controlled pressure control
  • Assisted/controlled volume control
  • CPAP
  • BILEVEL
  • SIMV
  • MMV
  • PRVC
  • Apnoe Backup Ventilation
  • Option NIV

Options

  • Optional adaptive cuff pressure control
  • Optional patient-side CO2- and O2-measuring
  • Optional external display

Ventilator settings

Tidal volume50 - 2500 mL
Minute volume0.5 - 50 L/min
Insp. flow0 - 180 L/min
Insp. pressure0 - 90 mbar
Breath rate1 - 120 /min
Insp. time0.1 - 15 s
I:E1:6 - 6:1
Ramp0 - 10 s
PEEP0 - 50 mbar
FiO221 - 100 %
Sigh1/10 - 1/200 breaths, in a/c modi
Insp./Exp. pause15 s
Trigger sensitivity (flow)0.5 - 20 L/min
Trigger sensitivity (pressure)-1 - -10 mbar
Exp. flowtrigger5 - 90 % of insp. peak flow
AlarmsPressure, Vt, MV, flow, breaths, O2, CO2, cuff pressure

Pressure

DisplayP/V, pressure-curve, PEAK, PEEP, plateau, MEAN, MIN
AlarmsPressure (high/low), PEEP (high/low)

Flow

DisplayF/V, flow-curve, PEAK, insp., exp.
AlarmsFlow (high/low)

Volume

DisplayP/V, volume-curve, Vt, insp., exsp., leak, MV
AlarmsVolume (high/low), VT (high/low), leak

Fi/e, O2/CO2

DisplayValues insp. and exsp.
AlarmsPreset limits (high/low)

Apnea

AlarmsPreset limits (high/low)

Breath parameters

DisplayWOB, compliance, resistance, intrinsic PEEP, I:E, P 0.1
AlarmsPreset limits (high/low)

Screen

DisplayHigh resolution 10.4“ TFT-LCD-Color-Display (brightness manually or automatically adjustable)
Curves/GraphicsSimultaneously visualized by up to 8 dynamic curves / loop diagrams
Data connectionsLAN oder RS232

Trend

Trend storageAll monitored parameters, storage of max. and min values per time scale
Storage timeUp to 96 hours
DisplayChart graphic

Technical data

Dimensions (H/W/D)351 * 317 * 189 mm
Weight12 kg
Voltage115 - 230 VAC / 50 - 60 Hz
Power consumption70 W
Internal batterie12 V / 30 min
External batterie12 V oder 24 V / via DC/DC-Converter
Gas supplyO2 / Air by central gas supply, additional port for aux. O2 bottle
Gas pressure2.8 - 6 bar (280 - 600 kPa)

Environmental conditions

OperationStorage
Temperature10 - +40 °C-20 - +60 °C
Atmospheric pressure700 - 1060 hPa500 - 1060 hPa
Rel. air humidity0 - 90 %0 - 100 %

MythoVent Ventilator


MythoVent - Leading by innovative ideas

Modern ventilation modes

The system provides all modern ventilation modes and gives the doctor the highest flexibility in setting the parameters to adjust the ventilation to the exact needs of the patient.
To these settings belong the pressure support of the spontaneous breath and the fine tunable trigger for the mandatory breath with both pressure- and modern flow-triggering.
The fast and safe weaning of the patient from the mechanical ventilation is the main challenge for the intensive care medicine today. The MythoVent is designed to support and stabilize the spontaneous breath of the patient.

Optional adaptive cuff pressure control

Exceptional innovative is the intelligent cuff pressure control. The cuff pressure is adjusted automatically as an offset to the respiratory and PEEP pressure and provides a save closing pressure in the trachea. The cuff pressure curve is displayed as an overlay to the respiratory pressure curve.

Use of single- and dual-limb-system

The only part of the device that has to be cleaned, sterilized and disinfected is the aluminum-cassette. It can be removed fast and easy by a simple press of a button. Since the cassette consists of metal it is almost everlasting - even in permanent clinical use.
Through a simple change of the cassette, the MythoVent can be used with coaxial- as well as dual-limb breathing system with no problem.

Integrated intelligent drug-nebulizer

Another feature is the integrated pneumatic control unit for a drug nebulizer. The system MythoVent drives the nebulizer during the first 75 percent of the inspiratory phase. It is ensured that the drugs always reach the patient in the most effective way and the filter systems of the breathing circuit are kept free.

Integrated high resolution color display

The ventilator MythoVent offers a high resolution 6 channel 10.4“ LCD color display. It allows at the same time the display of up to 8 dynamic curves and 12 numeric fields for the display of ventilation parameters.
The display may be individually configured to the needs of the user by free arrangement and choice of color for the displayed parameters and measured curves.

Optional external display

The MythoVent and MythoVent2 have an optional port for connecting an additional monitor. The content of the internal display is mirrored on a large-sized TFT-screen, so that the curves and values can be read clearly even from greater distance.

Easy and fast alarm-limit-adaptation

Alarm limits for ventilation parameters may be set manually or automatically by the system. The trend graphic of the ventilation parameters during the last half hour helps to set the upper and lower limits easy and gradient adaptive.

Individual configurations

Individual settings — screen setup, alarm limits, ventilation- and monitoring-settings — can be stored one by one or all together as individual configurations and are then available every time.

Optional patient-side CO2- and O2-measuring

The exspiratory concentration is measured via a sample line connected to the front of the device. For that purpose a small sample volume is permanently extracted near the patient directly at the HME filter and guided to the device.

Leightweight design

Less weight and small dimensions allow highest flexibility in patient handling, mounting systems and in-house transportation.

Update/Upgrade with standart RS232 service interface

To remain up to date the MythoVent comes with a standart RS232 service interface. With this interface it is easily possible to upgrade the firmware and get new features.



Ventilation modes

  • Assisted/controlled pressure control
  • Assisted/controlled volume control
  • CPAP
  • BILEVEL
  • SIMV
  • MMV
  • PRVC
  • Apnoe Backup Ventilation
  • Option NIV

Options

  • Optional adaptive cuff pressure control
  • Optional patient-side CO2- and O2-measuring
  • Optional external display

Ventilator settings

Tidal volume50 - 2500 mL
Minute volume0.5 - 50 L/min
Insp. flow0 - 180 L/min
Insp. pressure0 - 90 mbar
Breath rate1 - 120 /min
Insp. time0.1 - 15 s
I:E1:6 - 6:1
Ramp0 - 10 s
PEEP0 - 50 mbar
FiO221 - 100 %
Sigh1/10 - 1/200 breaths, in a/c modi
Insp./Exp. pause15 s
Trigger sensitivity (flow)0.5 - 20 L/min
Trigger sensitivity (pressure)-1 - -10 mbar
Exp. flowtrigger5 - 90 % of insp. peak flow
AlarmsPressure, Vt, MV, flow, breaths, O2, CO2, cuff pressure

Pressure

DisplayP/V, pressure-curve, PEAK, PEEP, plateau, MEAN, MIN
AlarmsPressure (high/low), PEEP (high/low)

Flow

DisplayF/V, flow-curve, PEAK, insp., exp.
AlarmsFlow (high/low)

Volume

DisplayP/V, volume-curve, Vt, insp., exsp., leak, MV
AlarmsVolume (high/low), VT (high/low), leak

Fi/e, O2/CO2

DisplayValues insp. and exsp.
AlarmsPreset limits (high/low)

Apnea

AlarmsPreset limits (high/low)

Apnea

AlarmsPreset limits (high/low)

Breath parameters

DisplayWOB, compliance, resistance, intrinsic PEEP, I:E, P 0.1
AlarmsPreset limits (high/low)

Screen

DisplayHigh resolution 10.4“ TFT-LCD-Color-Display (brightness manually or automatically adjustable)
Curves/GraphicsSimultaneously visualized by up to 8 dynamic curves / loop diagrams
Data connectionsLAN oder RS232

Trend

Trend storageAll monitored parameters, storage of max. and min values per time scale
Storage timeUp to 96 hours
DisplayChart graphic

Technical data

Dimensions (H/W/D)351 * 317 * 189 mm
Weight12 kg
Voltage115 - 230 VAC / 50 - 60 Hz
Power consumption70 W
Internal batterie12 V / 30 min
External batterie12 V oder 24 V / via DC/DC-Converter
Gas supplyO2 / Air by central gas supply, additional port for aux. O2 bottle
Gas pressure2.8 - 6 bar (280 - 600 kPa)

Environmental conditions

OperationStorage
Temperature10 - +40 °C-20 - +60 °C
Atmospheric pressure700 - 1060 hPa500 - 1060 hPa
Rel. air humidity0 - 90 %0 - 100 %